loading

Copper Cables

 ANSIAmerican National Standard Institute
ANSI MC 96.1Temperature measurement thermocouples
BSBritish Standard Institution
BS 4937International thermocouple reference tables
BS 5308Standard for instrumentation cables (Superseded, replaced by BS EN 50288-7. As design guide lines, now available PAS 5308)
BS 5839-1Fire detection and alarm system for building. Code of practice
BS 6387Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
BS 6425-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
BS 6425-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
BS 6724, Appendix FMeasurement of smoke density using the 3 m test cube (Absorbance)
BS 7622Measurement of smoke density of electric cables burning under defined conditions (LT)
BS 8434Method of test for assessment of the fire integrity of electric cables
CEIItalian Electrotechnical Committee CEI
CEI 20-11  Insulating, sheathing and covering materials for low voltage
energy cables
CEI 20-22/2Fire tests on electric cables.  Fire propagation tests
CEI 20-22/3Test for vertical flame spread of vertically-mounted bunched
wires and cables
CEI 20-29Conductors of insulated cables
CEI 20-35/1Test for vertical flame propagation for a single insulated wire
or cable
CEI 20-36/1 Test for electrical cables under fire conditions. Circuit integrity
CEI 20-37/2-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
CEI 20-37/2-2Determination of degree of acidity (corrosivity) of gases by
measuring PH and conductivity
CEI 20-37/2-3Determination of degree of acidity of gases for cables by
determination of weighted average of pH and conductivity
CEI 20-37/3Metodi comuni di prova per cavi in condizioni di incendio – Misura della densità di fumo di cavi che bruciano in condizioni definite
CEI 20-37/4Toxicity index of gases emission
CEI 20-37/6Measurement of smoke density of cables burning under
defined conditions
CEI 46-143Sectional specification for instrumentation and control cables
CEI 65-20Thermocouples – Part 3: Tolerances and method to identify cable extension and compensation
DINDeutsches Institut fur Normung DIN
DIN 43710Thermospanungen und werkstoffe der thermopaare
DIN 47100Fernmeldeschnuere; Kennzeichnung der Adern, Farben der Aussenhuellen
DIN 60584Thermocouples
EEMUAEngineering Equipment and Material Users Ass.
EEMUA 133Specification for underground armoured cable protected against solvent penetration and corrosive attack
ENEuropean Norm
EN 50200Methods of test for resistance to fire of unprotected small cables for use in emergency circuit
EN 50266Test for vertical flame spread of vertically-mounted bunched wires and cables
EN 50267/2-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
EN 50267/2-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
EN 50288-7Sectional specification for instrumentation and control cables
EN 50362Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 50363Insulating, sheathing and covering materials for low voltage energy cables
EN 60228Conductors of insulated cables
EN 60332-1Test for vertical flame propagation for a single insulated wire or cable
EN 60332-2Test for vertical flame propagation for a single small insulated wire or cable
EN 61034Measurement of smoke density of cables burning under defined conditions
ICEA / NEMAInsulated Cables Engineers Association / National Electrical Manufacturers Association
ICEA S-73-532Standard for Control, Thermocouple Extension, and Instrumentation Cables
IECInternational Electrotechnical Commission
IEC 60092-3Cables: construction, testing and installation
IEC 60228Conductors of insulated cables – Guide to the dimensional limits of circular connectors
IEC 60331Test for electrical cables under fire conditions. Circuit integrity. 
 IEC 60331Part 21 – Cables of rated voltage up to and including 0.6 / 1.0 kV 
 IEC 60331Part 23 – Electric data cables
 IEC 60331Part 25 – Optical fibre cables
IEC 60332-1Test on electric cables under fire conditions. Test on a single vertical insulated wire or cable
IEC 60332-2Test on electric cables under fire conditions. Test on a single small vertical insulated copper wire or cable
IEC 60332-3Test on electric cables under fire conditions.Test for vertical flame spread of vertically-mounted bunched wires or cables
IEC 60502Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV)
IEC 60754-1Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
IEC 60754-2Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity
IEC 60584Extension and compensating cables
IEC 61034-2Measurement of smoke density of electric cables burning under defined conditions (LT)
 IEEEInstitute of Electrical and Electronics Engineering
IEEE 383Standard for Type Test of Class 1E Electric Cables, Field Splices and Connections for Nuclear Power Generating Stations
 NEKStandard for Type Test of Class 1E Electric Cables, Field Splices and Connections for Nuclear Power Generating Stations
NEK 606Cables for offshore installations halogen-free and/or mud resistant
NFNorme Française
NF-C-32-070Essais de clasification des conducteurs et cables du point de vue de leur comportament au feu
NF-C-42-324Cables d’extention et de compensation pour couples thermoelectriques.Composition, nature des materiaux, essais de fabrication
NF-X-70-100Analyse de gaz de pyrolyse et de combustion
NF M 87-201Câbles d’extension ed de compensation pour thermocouples
NF M 87-202Industrie du pétrole – Câbles d’instrumentation
 UNIItalian National Unification Body
UNI 7938Thermocouples – Classification and static characteristics
 UTEUnion Tecnique de l’Electricitè
UTE C 20 -454Methode d’essai pour l’analyse et la dosage de gaz nocifs

Fibre Optic Cables

 BSBritish Standard Institution
BS 6425-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
BS 6425-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
BS 6724, Appendix FMeasurement of smoke density using the 3 m test cube (Absorbance)
 CEIItalian Electrotechnical Committee CEI
CEI 20-11Insulating, sheathing and covering materials for low voltage energy cables
CEI 20-22/2Prove di incendio su cavi elettrici. Prova di non propagazione dell’incendio
CEI 20-22/3 Test for vertical flame spread of vertically-mounted bunched wires and cables
CEI 20-35/1 Test for vertical flame propagation for a single insulated wire or cable 
CEI 20-36/2 -5 Test for electrical and optical cables under fire conditions. Circuit integrity.
CEI 20-36/4 Methods of test for resistance to fire of unprotected small cables for use in emergency circuit
CEI 20-36/5 Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
CEI 20-37/2-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
CEI 20-37/2-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
CEI 20-37/2-3Determination of degree of acidity of gases for cables by determination of weighted average of pH an conductivity
CEI 20-37/3 Measurement of smoke density of cables burning under defined conditions
CEI 20-37/4Toxicity index of gases emission
 ENEuropean Norms
EN 50200Methods of test for resistance to fire of unprotected small cables for use in emergency circuit
EN 50266Test for vertical flame spread of vertically-mounted bunched wires and cables
EN 50267/2-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
EN 50267/2-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
EN 60332-1Test for vertical flame propagation for a single insulated wire or cable
EN 60332-2Test for vertical flame propagation for a single small insulated wire or cable
EN 61034Measurement of smoke density of cables burning under defined conditions
 IECInternational Electrotechnical Commission
IEC/ISO 11801Information technology – Generic cabling for customer premises
IEC 60331Test for electrical and optical cables under fire conditions. Circuit integrity.Part 25 – Optical fibre cables
IEC 60332-1Test on electric and optical fibre cables under fire conditions. Test on a single vertical insulated wire or cable
IEC 60332-2Test on electric cables under fire conditions. Test on a single small vertical insulated copper wire or cable
IEC 60332-3Test on electric cables under fire conditions.Test for vertical flame spread of vertically-mounted bunched wires or cables
IEC 60754-1Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
IEC 60754-2Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity
IEC 60793Optical fibres
IEC 60794Optical fibre cables
IEC 61034-2Measurement of smoke density of electric cables burning under defined conditions (LT)
 ITU-TInternational Telecommunication Union
G.651.1Characteristics of a 50/125 μ μ m multimode graded index optical fibre cable for the optical access network
G.652Characteristics of a single-mode optical fibre and cable
G.655Characteristics of a non-zero dispersion-shifted single-mode optical fibre and cable
G.656Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport
G.657Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network
 NEKNorsk Elektroteknisk Komite
NEK 606Cables for offshore installations halogen-free and/or mud resistant
 NFNorme Française
NF-C-32-070Essais de clasification des conducteurs et cables du point de vue de leur comportament au feu
NF-X-70-100Analyse de gaz de pyrolyse et de combustion
 VDEVerband der Elektrotechnik
VDE 0888Optical fibre cables

Fire resistant cables

 BSBritish Standard Institution
BS 5266-1Emergency lighting. Code of practice for the emergency lighting of premises
BS 5839-1Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance
BS 5839-6Fire detection and fire alarm systems for buildings. Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings
BS 5839-8Fire detection and fire alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS 5839-9Fire detection and alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
BS 6387Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
BS 7211Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire
BS 7346-6Components for smoke and heat control systems. Specifications for cable systems
BS 7629-1Electric cables. Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Multicore and multipair cables
BS 7846Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification
BS 8434-2Methods of test for assessment of the fire integrity of electric cables. Test for unprotected small cables for use in emergency circuits. BS EN 50200 with a 930° flame and with water spray
BS 8491Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems
BS 8519Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice.
 CEIItalian Electrotechnical Committee CEI
CEI 20-11 / EN 50363Insulating, sheathing and covering materials for low voltage energy cables
CEI 20-36/2-1Tests for electric cables under fire conditions – Circuit integrity – Part 21: Procedures and requirements – Cables of rated voltage up to and including 0,6/1,0 kV
CEI 20-45Fire resistant elastomeric insulated cables, halogen free (LSOH) with rated voltage Uo/U 0.6/1 kV
 DINDeutsches Institut fur Normung
DIN 4102Fire behaviour of building materials and building components – Part 12: Circuit integrity maintenance of electric cable systems; requirements and testing
 EN European Norm
EN 50200Methods of test for resistance to fire of unprotected small cables for use in emergency circuit
EN 50266Test for vertical flame spread of vertically-mounted bunched wires and cables
EN 50267/2-1Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
EN 50267/2-2Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity
EN 50288-7Sectional specification for instrumentation and control cables
EN 50362Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
EN 50363Insulating, sheathing and covering materials for low voltage energy cables
EN 60228Conductors of insulated cables
EN 60332-1Test for vertical flame propagation for a single insulated wire or cable
EN 60332-2Test for vertical flame propagation for a single small insulated wire or cable
EN 60332-3Test for vertical flame spread of vertically-mounted bunched wires or cables
EN 61034Measurement of smoke density of cables burning under defined conditions
 IECInternational Electrotechnical Commission
IEC 60228Conductors of insulated cables – Guide to the dimensional limits of circular connectors
IEC 60331Test for electrical cables under fire conditions. Circuit integrity.
IEC 60332-1Tests on electric and optical fibre cables under fire conditions -Test for vertical flame propagation for a single insulated wire or cable 
IEC 60332-3Test on electric cables under fire conditions – Test for vertical flame spread of vertically-mounted bunched wires or cables
IEC 60502-1Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)IEC 60754-1Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables
IEC 60754-2Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity
IEC 60793-1Optical fibres
IEC 60794-1Optical fibre cables
IEC 61034-2Measurement of smoke density of electric cables burning under defined conditions (LT)
 NBNBelgian standards
NBN C 30-004Fire resistance of electical cables – Classification and test methods
NBN 713-020Fire resistance of building materials
 NFNorme Française
NF-C-32-070Insulated cables and flexible cords for installations – Classification tests on cables and cords with respect to their behaviour to fire
 SSSingapore Standard
SS 299 part 1Fire resistant cables – Performance requirements for cables required to maintain circuit integrity under fire conditions
 VDEVerband der Elektrotechnik Elektronik Informationstechnik
VDE 0815-814Wiring cables for telecommunication and data processing systems. Testing of cables, wires and flexible cords Continuance of insulation effect under fire conditions  Testing of cables, wires and flexible cords Continuance of insulation effect under fire conditions
VDE 0482-267Common test methods for cables under fire conditions – Test on gases evolved during combustion of materials from cables
VDE 0482-1034Measurement of smoke density of cables burning under defined conditions