| BS | British Standard Institution |
| BS 6425-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
| BS 6425-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
| BS 6724, Appendix F | Measurement of smoke density using the 3 m test cube (Absorbance) |
| CEI | Comitato Elettrotecnico Italiano |
| CEI 20-11 / EN 50363 |
Insulating, sheathing and covering materials for low voltage energy cables |
| CEI 20-22/2 | Prove di incendio su cavi elettrici. Prova di non propagazione dell’incendio |
| CEI 20-22/3 / EN 50266 |
Test for vertical flame spread of vertically-mounted bunched wires and cables |
| CEI 20-35/1 / EN 60332-1 |
Test for vertical flame propagation for a single insulated wire or cable |
| CEI 20-36/2 -5 IEC 60331-25 |
Test for electrical and optical cables under fire conditions. Circuit integrity. |
| CEI 20-36/4 - EN 50200 |
Methods of test for resistance to fire of unprotected small cables for use in emergency circuit |
| CEI 20-36/5 - EN 50362 |
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits |
| CEI 20-37/2-1 / EN 50267-2-1 |
Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
| CEI 20-37/2-2 / EN 50267-2-2 |
Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
| CEI 20-37/2-3 / EN 50267-2-3 |
Determination of degree of acidity of gases for cables by determination of weighted average of pH an conductivity |
| CEI 20-37/3 - EN 61034 |
Measurement of smoke density of cables burning under defined conditions |
| CEI 20-37/4 | Determinazione dell’indice di tossicità dei gas emessi dai cavi |
| EN | European Norm |
| EN 50200 | Methods of test for resistance to fire of unprotected small cables for use in emergency circuit |
| EN 50266 | Test for vertical flame spread of vertically-mounted bunched wires and cables |
| EN 50267/2-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
| EN 50267/2-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
| EN 60332-1 | Test for vertical flame propagation for a single insulated wire or cable |
| EN 60332-2 | Test for vertical flame propagation for a single small insulated wire or cable |
| EN 61034 | Measurement of smoke density of cables burning under defined conditions |
| IEC | International Electrotechnical Commission |
| IEC/ISO 11801 | Information technology - Generic cabling for customer premises |
| IEC 60331 | Test for electrical and optical cables under fire conditions. Circuit integrity.Part 25 - Optical fibre cables |
| IEC 60332-1 | Test on electric and optical fibre cables under fire conditions. Test on a single vertical insulated wire or cable |
| IEC 60332-2 | Test on electric cables under fire conditions. Test on a single small vertical insulated copper wire or cable |
| IEC 60332-3 | Test on electric cables under fire conditions.Test for vertical flame spread of vertically-mounted bunched wires or cables |
| IEC 60754-1 | Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
| IEC 60754-2 | Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity |
| IEC 60793 | Optical fibres |
| IEC 60794 | Optical fibre cables |
| IEC 61034-2 | Measurement of smoke density of electric cables burning under defined conditions (LT) |
| ITU-T | International Telecommunication Union |
| G.651.1 | Characteristics of a 50/125 μ μ m multimode graded index optical fibre cable for the optical access network |
| G.652 | Characteristics of a single-mode optical fibre and cable |
| G.655 | Characteristics of a non-zero dispersion-shifted single-mode optical fibre and cable |
| G.656 | Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport |
| G.657 | Characteristics of a bending loss insensitive single mode optical fibre and cable for the access network |
| NEK | Norsk Elektroteknisk Komite |
| NEK 606 | Cables for offshore installations halogen-free and/or mud resistant |
| NF | Norme Française |
| NF-C-32-070 | Essais de clasification des conducteurs et cables du point de vue de leur comportament au feu |
| NF-X-70-100 | Analyse de gaz de pyrolyse et de combustion |
| VDE | Verband der Elektrotechnik |
| VDE 0888 | Optical fibre cables |