firecel
Home » Prodotti » Cavi resistenti al fuoco » FIRECEL SR 125 RF1

FIRECEL SR 125 RF1

  • U-SR/OS/LSZH 300 V
     

Approved by ISIB
(Institut de Securite
Incendie - Belgium)

 

Applications

FIRECEL SR 125 RF1 are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.

Operating temperature

-40°C to +90°C

Minimum bending radius

10 times the outer diameter.

Colour code

Single pair white - blue
Multipair white - blue numbered

Applicable Standards

Fire resistant NBN C 30-004 (cat. F3) / NBN 713-020 (RF1) /
EN 50200 (PH90) / IEC 60331-23
Fire retardant NBN C 30-004 (cat. F2) / EN 50266-2-4 (cat. C) /
IEC 60332-3-24 (cat. C)
Flame retardant NBN C 30-004 (cat. F1) / EN 60332-1-2 / IEC 60332-1-2
Acid gas emission EN 50267-2-1 / IEC 60754-1
EN 50267-2-2 / IEC 60754-2
Smoke density EN 61034-2 / IEC 61034-2

Cable construction

Conductors

Solid plain annealed copper wire.

Insulation

High performance fire resistant silicone rubber.

Cable elements

Insulated cores are twisted to form pairs.
Two-pair cable had four cores laid in quad formation.

Cabling

Three pairs are cabled together.

Flame barrier

Glass tape.

Overall screen

Aluminium/polyester tape with tinned copper drain wire.

Outer sheath

LSZH thermoplastic material.
Colour orange (other colours on request).