This is an alternative to lead sheathed cables and can be used in cable tray, conduit or direct burial to connect different types of thermocouple in industrial process controls. This protection has lower weight and smaller diameter compared to lead sheath.
Excellent protection against corrosion, humidity, in petrochemical plants.
-20 °C to +80 °C (for general use);
-40 °C to +90 °C (on request).
20 times the outer diameter.
| BS 5308 or EN 50288-7 |
Basic design |
| IEC 60332-1 | Flame retardant |
| IEC 60754-1 | Halogen free properties (only for LSZH cables) |
| IEC 61034-2 | Low smoke emission (only for LSZH cables) |
Calibration and colours according to BS - DIN - NF - UNI.
Stranded conductors.
Galvanized steel tape armour (GSTA).
Sheath materials can be provided for excellent water, oil, hydrocarbons, UV resistance or other special request.
Fire retardant to IEC 60332-3 cat. C or A.
Solid alloy.
ANSI MC 96.1 or IEC 60584-3.
PVC, PE, XLPE or LSZH thermoplastic material.
The insulated cores shall be twisted in pairs/triads for a good reduction of the electromagnetic noise.
Aluminium/polyester tape, coverage >100%, aluminium in contact with tinned copper drain wire.
The screened pairs are cabled with suitable non hygroscopic fillers (when necessary) and wrapped with polyester tape if required.
Aluminium/polyester tape, coverage >100%, aluminium in contact with tinned copper drain wire.
Aluminium tape coated with a protective plastic coating, longitudinally applied, bonded to black extruded bedding of High Density Polyethylene compound plus an additional Polyamide-Polypropylene special thermoplastic alloy.
Single layer of galvanized steel wires (SWA).
PVC or LSZH thermoplastic material.